Menu
Latest
12 meetings · Prague, Jeju · 12–16 Oct
Reports
RAN1#126-bis · SA2#177

Glossary term · Radio Access Network

Active DL BWP

Active Downlink Bandwidth Part

Radio Access Network →

Active DL BWP is a downlink bandwidth part currently in use by a UE for reception, determining the portion of carrier bandwidth monitored for PDCCH, PDSCH, and reference signals to enable bandwidth adaptation in 5G NR.

Introduced
Rel-15
Where
User Equipment
Specifications
2 specs
Active DL BWP Description Purpose What changed Neighbours Specifications

Description

Active DL BWP (Active Downlink Bandwidth Part) is a 5G NR concept introduced in Rel-15 as part of the bandwidth part (BWP) framework. A carrier in NR can be up to 400 MHz wide, but a UE is not required to support the full carrier bandwidth. Instead, the carrier is divided into bandwidth parts, each with its own numerology (subcarrier spacing), and the UE is configured with one or more DL BWPs. At any given time, exactly one DL BWP is active for a UE in a serving cell (with the exception of the initial BWP during initial access). The active DL BWP defines the frequency range within which the UE receives PDCCH, PDSCH, CSI-RS, and other downlink signals.

The active DL BWP is configured via RRC signalling (BWP-Downlink IE) and switched via DCI (Bandwidth Part Indicator field) or by RRC reconfiguration. The network can switch the active DL BWP to adapt to traffic conditions: a narrow BWP saves UE power and reduces blind decoding complexity, while a wide BWP enables high throughput. The active DL BWP is also tied to the active UL BWP through the BWP pairing configured by the network, although the two can be switched independently in some cases.

In terms of physical-layer procedures, the active DL BWP determines the CORESET and search space configuration, the PDSCH resource allocation granularity, and the reference point for frequency-domain resource allocation. The UE must not receive outside the active DL BWP, and the network must ensure that all downlink transmissions to the UE fall within it. The active DL BWP also affects the UE's RF requirements: the UE only needs to meet its RF performance requirements within the active BWP, which is why BWP switching is used for power saving.

The initial DL BWP is used before RRC configuration and is defined by the MIB and SIB1. After RRC setup, the network configures dedicated BWPs and indicates which one is the initial active DL BWP. The default DL BWP is used when the network does not explicitly indicate a BWP, for example after a BWP inactivity timer expires. The BWP inactivity timer is a key mechanism: if no DCI is received on the active DL BWP for a configured duration, the UE switches to the default DL BWP, which is typically narrower and more power-efficient.

Active DL BWP is defined in TS 38.213 (physical layer procedures) and referenced in TS 38.133 (RF requirements) and TS 38.533 (UE conformance). The term has remained stable across Rel-15 to Rel-20, with only editorial changes to the specification references. Its stability reflects the maturity of the BWP framework, which is now a fundamental part of NR operation.

Purpose & Motivation

Active DL BWP exists to solve the mismatch between the wide carrier bandwidths supported by 5G NR (up to 400 MHz) and the limited bandwidth capabilities of many UE categories, especially low-cost and power-sensitive devices. By defining a subset of the carrier as the active BWP, the network can serve UEs with different bandwidth capabilities on the same carrier, and can dynamically adapt the bandwidth to traffic demand.

The concept also enables significant power savings. A UE monitoring a narrow active DL BWP consumes less power than one monitoring the full carrier, which is critical for battery-powered IoT and wearable devices. The BWP inactivity timer and default BWP mechanism allow the network to automatically fall back to a narrow BWP when traffic is low.

Before BWP, LTE used a fixed system bandwidth per cell, and all UEs had to support it. NR's BWP framework decouples the carrier bandwidth from the UE bandwidth, providing flexibility for network deployment and UE design. The active DL BWP is the runtime manifestation of this flexibility.

What changed in its specifications

The latest release-to-release comparison of specifications that define Active DL BWP. Each summary describes the whole specification, not only this term.

TS 38.133Rel-18 → Rel-19

Rel-19 adds low band carrier aggregation via switching and low-power wake-up receiver (LP-WUR) requirements to TS 38.133. It also adds ATG network support, intra-band non-collocated NR-CA receiver types, and multi-carrier BWP switch and SCell activation delay requirements.

Full comparison in TS 38.133 →

Release Timeline

Evolution Across Releases

An overview written from the defining specifications, not a verified change history. For the exact text, open the specifications listed below.

Rel-15 Initial

Initial definition introduced with the NR BWP framework: active DL bandwidth part as defined in TS 38.213, enabling bandwidth adaptation and UE capability matching.

Definition carried over unchanged from Rel-15.

Definition carried over unchanged from Rel-15.

Definition carried over unchanged from Rel-15.

Wording changed editorially: the specification reference was updated to 'as defined in 3GPP TS 38.213 [8]', adding the '3GPP' prefix and renumbering the reference.

Wording changed editorially: the reference reverted to 'as defined in TS 38.213 [3]', restoring the shorter form and original reference number.

Defining Specifications

3GPP specifications that define or reference Active DL BWP, with the latest known release. Sourced from the 3GPP document catalog — see methodology.

SpecificationTitleRelease
TS 38.133 vk10 NR Radio Resource Management Requirements Rel-20 read
TS 38.533 vj40 NR UE RRM Conformance Testing Rel-19 read